Release notes for SambaRack Manager, including new features, enhancements, and fixes.Documentation Index
Fetch the complete documentation index at: https://sambanova-systems.mintlify.dev/docs/llms.txt
Use this file to discover all available pages before exploring further.
SambaRack Manager v1.0.57 release
Release Date: April 30, 2026 This release introduces 2-PDU configuration support for SambaRack SN40L-16 and a new firmware update command for BIOS, BMC, card, and XRDU device types.New features and enhancements
SambaRack SN40L-16: 2-PDU configuration support SambaRack Manager now supports the 2-PDU SambaRack SN40L-16 configuration (part numberP-1002331) alongside the existing 4-PDU configuration (part number 1001934).
snctl rack addaccepts part numberP-1002331; the component list reflects the actual PDU count.snctl rack listshowsType: P-1002331andPDUs: 2for 2-PDU racks.snctl rack showshows onlyPDU/1andPDU/2for 2-PDU racks.- The device index table is updated to reflect 1–4 (4-PDU config) or 1–2 (2-PDU config).
snctl device firmware-update command is now available for BIOS, BMC, card, and XRDU device types.
- Use
--rack-idor--groupto select the target; use--indexto target a specific XRDU (single, comma-separated list, or all). - Use
--filefor a custom firmware file; use--forceto skip pre-condition checks. - When upgrading multiple components in the same maintenance window, follow this order: THOR CARD → BIOS → BMC → XRDU.
- XRDUs within a rack are upgraded in parallel; racks within a group are processed sequentially.